|
Product Links Heat Pumps Under-floor Fan-coils DIY Kits Conversion Kits Convert your oil or gas
system |
Nordic Geothermal Heat
pumps Under-floor Fan-coils DIY kits Under-floor Heating Nordic Geothermal can provide the customer with the complete package.
The customer can choose air or water source heat pumps, under-floor,
fan-coils or aluminium radiators in any combination and can also choose
heating only, heating and cooling or either with domestic hot water
production. If you have CAD drawings of your building please e-mail them to us for
a quote. If you only have sketches you can scan and e-mail these and we will
produce a CAD drawing to use for your quote, free of charge. The typical under-floor package includes a detailed piping plan of
your building, and designed and delivered to site within 7 to 10 working days
of order, to any of the countries in Europe that we serve. The package normally includes: ˇ
15mm Under-floor Heating
Barrier pipe (BS 7291 Class S approved). ˇ
19mm Corrugated ducting
for protection of pipe-work if needed. ˇ
Under-floor Heating
manifolds located throughout. ˇ
Thermostatic mixing valve
located at each manifold. ˇ
Digital thermostats for
control of each individual zone, with night-time set-back facility. ˇ
Rapid Rail fixing system
for fixing of pipe-work to insulation. ˇ
Grundfos 25/65
circulating pump located at each manifold. ˇ
Full design specification
including all necessary schematics. ˇ
Installation DVD ˇ
Printed manual Not
supplied: Primary
pipe-work from boiler house to manifold locations. Insulation
to be laid prior to installation of pipe-work as well as edge insulation for
all external walls. Modern under-floor heating systems are clean,
comfortable, and economical to run, virtually maintenance free and offer
tremendous energy saving potential. Advantages of under-floor? Conventional heating systems (using convector
radiators) provide warmth within a space or building by heating the air in
the room. By comparison, UFH transfers heat from a very large surface area,
which is only slightly warmer than the room. Floors are warmer and the floor
to ceiling temperature and humidity levels remain more constant producing a
more comfortable environment for occupants. The heated floor operates at low
temperatures and will not cause convection drafts or circulation of dust
within the room. The floor surface temperature required is usually
quite low and very close to the actual room temperature and always below 29ēC
in occupied areas to achieve an acceptable degree of comfort. It is essential however, that floor coverings do
not provide too great a degree of insulation or the heat in the UFH system
may be able to raise the room temperature to its design level. The basic
operation of an under-floor heating system is pipe embedded within a concrete
screed with warm water circulating through the pipe work allowing for the
gradual heating of the screed and eventual emitting of heat from the floor
into the room. The heat is concentrated where it is most needed for human comfort
and energy efficiency. For a detailed quotation for your building, please Contact Us
with details of your building. To get detailed information on any of our products, please click on
the relevant tab on the left of your screen. Current Oil
Price Oil price was $36.51 on 16th Jan 2009. What is it now? |
|
|
|